Basics of Biomedical Instrumentation Systems

Key Performance Requirements of Effective Biomedical Instrumentation Systems

The information obtained from a medical sensor or transducer is usually in form of current intensity, voltage level, frequency or signal phase relative to a standard.

Biomedical Instrumentation Systems

We look at some of the performance requirements considered in biomedical instrumentation systems as discussed below:

  • To make accurate measurements of voltage, it is necessary to have the input impedance of the measuring device larger than the output impedance of the signal source. This is to minimize the error that would occur if an appreciable fraction of the signal source were dropped across the source impedance.
  • An accurate measurement of current source signals requires that the source output impedance be larger than receiver input impedance. In an ideal situation, a receiver that exhibits zero input impedance would not cause any disturbance to the current source. Hence, high-impedance current sources are more easily handled than low-impedance current sources.
  • Generally, the frequency response of the system should be compatible with the operating range of the signal being measured. To process the signal waveform without distortion, the bandpass of the system must include all of the frequency components of the signal that contribute significantly to the signal strength. The range can be determined quantitatively by obtaining a Fourier analysis of the signal.
  • Electrical signals are usually affected by spurious signals components or noise. Biomedical instruments are designed in such a way that the noise is minimized to enable accurate and sensitive measurement. To extract information from noisy signals, it is necessary to enhance signal-to-noise ratio. Using techniques like bandwidth reduction.
  • Digital processing is preferred over analog processing. Digital techniques are advantageous over analog techniques e.g. they are not affected by temperature that affects analog devices. The digital devices have a powerful performance since they are able to implement complex algorithms.

Related: Key factors to consider when designing Biomedical Instruments

Share
John Mulindi

John Mulindi has a background in Instrumentation, and he writes on various topics ranging from Technical, Business to Internet marketing fields. He likes reading, watching football, writing and taking on adventure walks in free time.

View Comments

Recent Posts

Confocal Laser Scanning Microscopy (CLSM)

Confocal Microscopy Technique In conventional microscopy, the specimen is usually mounted on a glass slide…

2 months ago

Principle of Working of a Demand Cardiac Pacemaker

A cardiac pacemaker is normally used to produce pulses that force the heart to beat…

2 months ago

What is Electroporation?

Electroporation is a technique that utilizes intense pulses of electricity to ‘punch’ holes in cell…

3 months ago

What is Single Photon Emission Tomography (SPECT)?

Single Photon Emission Tomography (SPECT) is a technique for producing 3D images from 2D images…

3 months ago

Polarographic Clark Electrodes

Polarographic electrodes differ from the typical pH and ion specific cells in that a polarographic…

6 months ago

Scintillation Counters: Operation & Application in Medical Imaging

Scintillation counters are basically made up of the following main components: a scintillation material (crystal),…

6 months ago